Products

State Enterprise “Kharkiv Instrument-Making Plant named after T. H. Shevchenko” (SE KhIMP named after T. H. Shevchenko) is a multidisciplinary structured instrument-making enterprise based on the traditions and centuries of experience in the field of industrial production, specializing in high-level electronics.

The products of our enterprise are used in the most high-tech industries: energy, communications, transport, medicine, military equipment. The plant named after T. H. Shevchenko is one of the few enterprises in Ukraine, which has its own design bureau, required staff of highly skilled specialists and technical capabilities for development, as well as full support of the production of electronic devices.

PRODUCTION QUALITY

The enterprise constantly maintains reliable control over the quality of products, because we not only produce high precision electronic devices, but also carry out their debugging for successful commissioning and repair, if necessary.
The activity of our enterprise and the quality of finished products have been recognized internationally. Executive Committee of the international organization “Business Initiative Directions” awarded the SE KhIMP named after T. H. Shevchenko for the high image of the enterprise and high quality of products with the following awards:

We are responsible for the quality of our products, so if you have any questions about it, you can contact our product quality specialist.

MAIN PROCESSES USED IN THE PRODUCTION AT THE ENTERPRISE:

    • mechanical, electrical and electronic assemblies of equipment;
    • production of microelectronics;
    • regulation and all types of automated testing of equipment quality;
    • machining of metal of the first and second class of accuracy and various types of stamping;
    • galvanic, paint and varnish coatings;
    • casting of ferrous, non-ferrous metals and alloys, as well as plastics on thermoplastics machines.

Products of the State Enterprise “Kharkiv Instrument-Making Plant named after T.H. Shevchenko “- devices and machinery of high precision for civil and military production.

CIVIL MANUFACTURING:

  1. electronic devices used in medicine;
  2. ACS TP of nuclear, thermal, hydro, wind power plants, gas stations and software;
  3. electronic digital automatic telephone exchanges (rural and office), cross-equipment and other means of telecommunication, security and alarm systems;
  4. development and implementation of software materials and complexes;
  5. products for rolling stock and stationary objects of transport enterprises;
  6. metro equipment and instruments household and industrial lamps (luminescent);
  7. cabinets for telecommunication and power engineering;
  8. manufacture, regulation and delivery of VTK devices of any complexity, both mechanical and electronic parts.

MILITARY MANUFACTURING:

Hardware and devices that are parts of the T-80, T-84, “Oplot” combat vehicles

Product list:


UNIT BU43-2SM /
  The control unit of the loading mechanism

Purpose:

  • Control of the loading mechanism
  • During loading and unloading of
    the conveyor in automatic and
    semi-automatic modes;
  • Conveyor control;
  • Display control;
  • Providing recording, erasing, reading and storing information about
    the loading of the conveyor.

Operating mode (6±0.1) h with a subsequent interruption (1 ± 0.1)
Operating voltage range 22.5 ÷ 28.5 VDC
Weight ≤ 5.5 kg


PANEL PK43-2 / 
Соmmander’s panel

Commander’s panel designed for:

  • Control of the loading mechanism
    in automatic and semi-automatic
    modes;
  • Giving the commander information
    on the type and number of ammunitions loaded;
  • Provision of management of common equipment systems which
    functionally connected with the
    panel.

Operating mode (6±0.1) h with a subsequent interruption (1± 0.1) h.
Operating voltage range 22.5 ÷ 28.5 VDC
Weight ≤ 2.7


SENSOR D30-3S / 
Electrical circuit commutation sensor

The electrical circuit commutation sensor is designed for switching electrical circuits of automation.
Operating mode (12±0.1) h with a subsequent interruption (1± 0.1) h.

  • Switching voltage of direct current (0.2 ÷ 29) V
  • Switching frequency ≤ 10 per minute
  • Working stroke of the rod (0.25 ÷ 1) mm
  • The force at the working
    stroke of the rod(14.7 ÷ 29.4) N, (1.5 ÷ 3) kgf
  • Full stroke of the rod ≥ 6.1 mm
  • Weight ≤ 0.15 kg


SENSOR D20 / Gun stopper position sensor

The sensor is designed for switching electrical circuits of automatics
Operating mode (6± 0.1) h with a subsequent interruption (1 ± 0.1) h

  • Switched DC voltage………(22.5 ÷ 28.5) V
  • Switching frequency……≤ 12 per minute
  • Effort at an operating cycle of the sensor rod of 6 mm 4.5 kgs max
  • Weight ≤ 0.35 kg


SENSOR DPK78-1 /
  Conveyor position sensor

The conveyor position sensor is designed to make a signal proportional to the angle of rotation of the conveyor relative to the loading line.

Operating mode (12±0.1) h with a subsequent interruption (1± 0.1) h.
Operating voltage range 18 ÷ 27 V
The operating frequency ange 400 ÷ 1000 Hz
Weight ≤ 0.3 kg


UNIT 9S517 /
  Block automatic

The unit is designed for:

  • Control of device’s information
    block of the product 9К119;
  • Provision of connection of control
    equipment to the 9K119 product
    during maintenance.

Operating mode (6±0.1) h with a subsequent interruption (1 ± 0.1) h
The range of operating voltages (in the chain AZR-U-B) 22.5 ÷ 28.5VDC


UNIT BZ-1M / 
Protection unit

Designation:

  • Protection of consumers by AC circuits 36 V AC, 400 Hz, of I and III phases, coming from a PT-800 or PN-800 standard transducer

Operating mode (6±0.1) h with a subsequent interruption (1± 0.1) h
Operating voltage range 22.5 ÷ 28.5 V DC
The range of working alternating voltages with frequency (400 ± 8) Hz (36 ± 1,2) V
Weight ≤ 2.5 kg


UNIT KP1-1S / 
Relay unit

Designation:

  • Switching of DC circuits in the automatic system.

Operating mode (6±0.1) h with a subsequent interruption (1 ± 0.1) h
The range of operating voltages 22.5 ÷ 28.5 V DC


BOX K2 /
  Distribution boxes

It is intended for placing the starting elements of the electric motor of the electric power amplifier of the horizontal pointer drive.

Operating mode (6 ± 0.1) h with a subsequent interruption (1± 0.1) h.
The range of operating voltages 22.5 ÷ 28.5 V DC
Weight ≤ 4.4 kg


OG / Angle limiter

It is intended for switching electrical interlocks circuits of the system when the gun approaches the limiting elevation or decrease angles and when moving away from them.

Operating mode (6 ± 0.1) h with a subsequent interruption (1 ± 0.1) h
The range of operating voltages 22.5 ÷ 28.5 V DC
Weight ≤ 0.95 kg


PP ACTUATING DEVICE  /
  Device bringing guns to the angle charging

Designed to generate the signals necessary to bring the gun to the loading angle.

Operating mode (6 ± 0.1) h with a subsequent interruption (1± 0.1) h.
The range of operating voltages 22.5 ÷ 28.5V DC
Weight ≤ 1.4 kg


SENSOR D74M /
  Sensor stopper tower

The sensor is designed for switching electrical circuits of automatics.

Operating mode (6 ± 0.1) h with a subsequent interruption (1 ± 0.1) h
Switching voltage …… (22,5 ÷ 28,5) V DC
Switching frequency …. ≤ 12 per minute
Operating cycle of the rod …… 1 ÷ 2 mm
Effort at operating cycle of the sensor rod ≤ 3 kgf
Weight ≤ 0.35 kg

Hardware and devices, which are included as components of T-64, T-72, “Bulat” combat vehicles

Product list:


UNIT BV29 /  Unit of vertical guidance of an antiaircraft machine gun

The unit of vertical guidance of an antiaircraft machine gun is intended for:

  • electric motor control EDM-14 electric drive of vertical pointing of an antiaircraft machine gun in the «Automatic» and «Semi-automatic» mode;
  • the inclusion of the AMG electromagnet;
  • to provide compensation for the non-synchronous transmission of the angle over vertical pointing when the antiaircraft machine gun is
    operating in the «Automatic» mode.

Operating mode (6±0.1) h with a subsequent interruption (1± 0.1) h.
Operating voltage range 22.5 ÷ 28.5 VDC
Weight ≤ 5.5 kg


UNIT BG29 /  Unit of horizontal guidance of an antiaircraft machine gun

The unit of horizontal guidance of an antiaircraft machine gun is designed for:

  • control of the ED-76 electric motor of the horizontal drive;
  • the formation of the «Target designation» mode;
  • formation of the «Override» mode;
  • control in the «Override» mode;
  • formation of «TS‑TShU» modes.

Operating mode (6±0.1) h with a subsequent interruption (1 ± 0.1) h
Operating voltage range 22.5 ÷ 28.5 VDC
Weight ≤ 6 kg


UNIT BРV29 / 
Unit of guidance of AMG and the main armament 

The control unit of the antiaircraft machine gun and the main armament is intended for:

  • inclusion of the «Target designation» mode;
  • inclusion of the «Override» mode;
  • switching on modes and output signals of the electric drives control of the 1EC29 (1EC29-01) system.

Operating mode (6±0,1) h with a subsequent interruption (1± 0,1) h.
Operating voltage range 2.5 ÷ 25.5 V DC
Three-phase voltage supply is (36±1.2) V AC with frequency (400±8) Hz. Current consumption is 0.1 A per phase


Sensor DRL
  /  Right-hand manhole position sensor

The right-hand manhole position sensor is an angular position sensor.

Operating mode (12±0.1) h with a subsequent interruption (1 ± 0.1) h
Operating voltage (27 ± 1) V
Frequency (400 ± 8) Hz
Weight ≤ 1.2 kg


SENSOR D30-3S / 
Electrical circuit commutation sensor

The electrical circuit commutation sensor is designed for switching electrical circuits of automation.

Operating mode (12±0.1) h with a subsequent interruption (1± 0.1) h
Switching voltage of direct current (0.2 ÷ 29) V
Switching frequency ≤ 10 per minute
Working stroke of the rod (0.25 ÷ 1) mm
The force at the working stroke of the rod(14.7 ÷ 29.4) N, (1.5 ÷ 3) kgf
Full stroke of the rod ≥ 6.1 mm
Weight ≤ 0.15 kg


UNIT BU43-2SM /
  The control unit of the loading mechanism

Purpose:

• Control of the loading mechanism during loading and unloading of the conveyor in automatic and semi-automatic modes;
• Conveyor control;
• Display control;
• Providing recording, erasing, reading and storing information about the loading of the conveyor.

Operating mode (6±0.1) h with a subsequent interruption (1 ± 0.1) h
Operating voltage range 22.5 ÷ 28.5 VDC
Weight ≤ 5.5 kg


PANEL PN43-2S / 
Ganner’s panel

Designation:

  • ensuring control of the loading mechanism in automatic mode;
  • ensuring control of general equipment systems of the product which functionally connected with the panel

Operating mode (6±0.1) h with a subsequent interruption (1 ± 0.1) h
The range of operating voltages 2.5 ÷ 28.5 VDC
Weight ≤ 2.0 kg


PANEL PK43-2 / 
Соmmander’s panel

Commander’s panel designed for:

  • control of the loading mechanism in automatic and semi-automatic modes;
  • giving the commander information on the type and number of ammunitions loaded;
  • provision of management of common equipment systems which functionally connected with the panel.

Operating mode (6±0.1) h with a subsequent interruption (1± 0.1) h.
Operating voltage range 2.5 ÷ 28.5 VDC
Weight ≤ 2.7 kg


SENSOR DPK78-1 /
  Conveyor position sensor

The conveyor position sensor is designed to make a signal proportional to the angle of rotation of the conveyor relative to the loading line.

Operating mode (12±0.1) h with a subsequent interruption (1± 0.1) h.
Operating voltage range 18 ÷ 27 V
The operating frequency ange 400 ÷ 1000 Hz
Weight ≤ 0.3 kg


UNIT BU-K1 /
  Main gun stabilization and control unit

Designation:

Processing of incoming signals from the sensors, its converting them and generating of output voltage and current that control the drives, which provide stabilized guidance of the gun in vertical and horizontal directions.

Operating mode (6± 0.1) h with a subsequent interruption (1± 0.1) h.
Operating voltage range 22.5 ÷ 28.5 VDC
Weight ≤ 15 kg


UNIT 9S517 /
  Block automatic

The unit is designed for:

  • control of device’s information block of the product 9К119;
  • provision of connection of control equipment to the 9K119 product during maintenance.

Operating mode (6±0.1) h with a subsequent interruption (1 ± 0.1) h
The range of operating voltages (in the chain AZR-U-B)… 22.5 ÷ 28.5VDC


UNIT BZ-1M / 
Protection unit

Designation:

  • protection of consumers by AC circuits 36 V AC, 400 Hz, of I and III phases, coming from a PT-800 or PN-800 standard transducer.

Operating mode (6±0.1) h with a subsequent interruption (1± 0.1) h
Operating voltage range 22.5 ÷ 28.5 V DC
The range of working alternating voltages with frequency(400 ± 8) Hz (36 ± 1,2) V
Weight ≤ 2.5 kg


UNIT KP1-1S / 
 Relay unit

Designation:

  • switching of DC circuits in the automatic system.

Operating mode (6±0.1) h with a subsequent interruption (1 ± 0.1) h
The range of operating voltages 22.5 ÷ 28.5 V DC


UNIT 1V216 /
  Device for choosing the type of ammunition

The unit for choosing the type of ammunition when loading the conveyor is designed for switching electrical circuits of automation.

Switched voltage 22.5 ÷ 28.5 V DC
Switching current 450 ÷ 600 A
Weight ≤ 1.4 kg


DVE-BS / 
Wind sensor

It is intended for measuring the transverse component of wind speed and converting it into electrical signal.

Features:

  • Microprocessor control
  • Digital synthesis and processing of signals
  • Digital interface for control and diagnostics
  • Simplify construction
  • No need to use BS unit

Wind speed measurement range 0 ÷ 40 m/s
Wind speed measurement accuracy ±0,5 м/с
Temperature range –40°С ÷ + 85°С
Temperature accuracy ±1°С
Supply voltage 18 ÷ 35 V DC
Power consumption <10 VА


SHILI-1F /
  Laser warning system (raw unit) 

It is intended for photo detector registration of laser radiation, formation of output signals for subsequent processing on external devices.
The device generates signals for monitoring the communication channel of the head and external devices at the request of the crew.
Operating mode (6 ± 0.1) h with a subsequent interruption (1± 0.1) h.

The range of captured radiation (0,6 ÷ 1,9) μm
Sector review:

  • in the horizontal plane (135±8) °
  • in the vertical plane –5°÷ +25°

Operating temperature range –40°С÷ +60°С
Start up time 1 s
Mean time between failures not less than 550 h
Power consumption ≤ 10 VА


SHILI-2F /
  Laser warning system (accurate unit) 

IIt is intended for registration of laser radiation and its transformation into a digital code, formation of output signals for subsequent processing on external devices.
The device generates signals to control communication channel of the head and external devices at the request of the crew.
Operating mode (6± 0.1) h with a subsequent interruption (1 ± 0.1) h

The range of captured radiation (0,6 ÷ 1,9) μm
Sector review:

  • in the horizontal plane (45±3) °
  • in the vertical plane –5°÷ +25°

Operating temperature range −40°С÷ +60°С
Start up time 1 s
Mean time between failures not less than 550 h
Power consumption ≤ 10 VА


«Tucha» /
  Is a unified system for launching smoke grenades

Designation — setting smoke screens to camouflage actions or «blinding» the missile. Launching of grenades can be carried out one at a time or volley.
Consists of control panel and the launchers.
The launchers consist of a breech and contact device. They are fixed to brackets welded to the turret.
The control panel is designed for launching of smoke (aerosol) grenades.
The indication on the panel is used to signal the presence of smoke grenades in the launchers and to check the presence of the electrical circuit at maintenance.

Range of grenade launching –300 m
Duration of intensive smoke formation ≤ 2,5 min
Length of the smoke-screen 30 ÷ 45 m
Height of smoke-screen ~8 m


PN-800 / 
Three-phase static voltage converter

Three-phase static voltage converter is a new development — replacement of PT-800

Features:
Output frequency 400±1 Hz
Efficiency ≥ 83 %
Input current at no load < 1 A
Start up time 2 s
Acoustic noise ≤ 45 dBA
Input voltage range 19 ÷ 31 VDC
Operating temperature range − 40 °С ÷ +55 °С

For product sales, you can contact the head of the sales department of the
State Enterprise KhIMP named after T. H. Shevchenko:

+38 (050) 026-81-40